HVAC learning

Condensing boiler rooms training

This essential training will give you the ability to design and renovate a boiler system with or without DHW, having one or more condensing boilers. A level to master’s level.

188 STUDENTS ENROLLED
  • Profile photo of George
  • Profile photo of ernie salamone
  • Profile photo of Mick Clare
  • Profile photo of pladd
  • Profile photo of Roy
  • Profile photo of seo projectexpert

Description of the training Condensing boiler rooms:

 

 Condensing Boiler Systems  (without DHW, with 2 & 3 connections)

 

Objective:
To be able to design and renovate a boiler system without DHW, having one or more condensing boilers with 2 or 3 connections.

Level: A level equivalent to HDN.
Guidance: It is not enough to install condensing boilers, the condensation has to take place. The study of this e-book, A level equivalent to Master’s level, is essential for technicians in charge of design, installation and operation of these heating systems.

 

 Condensing boiler systems without DHW, 4 connections, recuperator – Part 1

 

Objective:
To be able to design or renovate a boiler system without domestic hot water production (DHW), composed of one or more condensing boilers with 4 connections, or one or more recuperators.

Level: HND to Master’s level.
Guidance: It is not enough just to install condensing boilers, the process of condensation has to take place. Studying this section at HND to Master’s level is essential for technicians in charge of the design the installation and the operation of these boilers.

 

Condensing boiler systems without DHW, 4 connections, recuperator – Part 2

 

Objective:
To be able to design or renovate a boiler system without domestic hot water production, composed of one or more 4 connection condensing boilers or one or more recuperators.

Level: HND to Master’s level.
Guidance: It is not enough just to install condensing boilers, the process of condensation has to take place. Studying this section at HND to Master’s level is essential for technicians in charge of the design, the installation and the operation of these boilers.

 

Condensing boilers with DHW – Part 1

 

Objective:
To be able to design or renovate a heating system with DHW production, having one or more 2 or 3 connection condensing boilers.

Level: HND to Master’s level.
Guidance: It is not enough to fit condensing boilers; the condensation has to take place. The study of this e-book, from HND to Master’s level, is essential for technicians in charge of the design, installation and operation of these heating systems.

 

 Condensing Boilers with DHW – Part 2

 

Objective:
To be able to design or renovate a heating system with DHW production, having one or more condensing boilers,  4 or 6 connection, or one or more recuperators.

Level: HND to Master’s level.
Guidance: It is not enough to fit condensing boilers; the condensation has to take place. The study of this e-book, equivalent to HND to Master’s level, is essential for technicians in charge of thedesign, installation and operation of these heating systems.

Course Reviews

No Reviews found for this course.